Seite 1 - 1.3 User Guide

Self-Positioning Handheld 3D ScannerZScan™1.3 User GuideZScan: Version 1.3POWERED BY

Seite 2

8Connecting the scannerThe first step is to turn on the computer.Safely place the ZScanner 700 on its stand.Figure 1.2 Position of the ZScanner 700 on

Seite 3 - CAUTION NOTES

9Storing your ZScanner 700First of all, the calibration plate should be stored at the bottom of the case,underneath the foam. The calibration plate is

Seite 4 - LASER WARNING

10Figure 1.6 System content stored properlySpecificationsFeaturesValuesLaser class IIWave length 660nm (0.000026 in)Depth of field 300 mm (12 in)Power

Seite 5 - WARNING LABELS AND LOCATIONS

11ConceptThe ZScanner 700 was designed to allow easier and faster digitization. With itseasy to use interface, this system does not require any specif

Seite 6 - WHAT’S NEW

12ZScanZScan minimal required configuration Processor with HT (Hyper Threading) or Dual Core technology (Dual Corerecommended). Dedicated Graphical

Seite 7 - System Overview

13Figure 2.1 - System connectionsZScan Software installationIf the computer was purchased from Z Corporation with the ZScanner 700 sensor, thesoftware

Seite 8 - Figure 1.1 - ZScanner 700

14Figure 2.2Click Next to access installation options.

Seite 9

15Figure 2.3Select components to install and click “Next”.Note that if you wish to install the plug-in for Geomagic, it must already beinstalled. If t

Seite 10 - Connecting the scanner

16Figure 2.4Select installation folder with the Browse button. Select in which profile theinstallation should be done. The “Everyone” option is recomm

Seite 11 - Storing your ZScanner 700

17Figure 2.6The ZScan file manager window will open. You can select the configuration fileand the license file.Every ZScanner 700 sensor has its own c

Seite 12 - Specifications

iiCAUTION NOTES...1LASER WARNING...

Seite 13

18License and configuration files updateIf the sensor has been recalibrated after maintenance or if a new license hasbeen generated for you, you may h

Seite 14

19General ConceptsFile Types.CLFCLF is the license that makes ZScan functional. A specific license is required foreach ZScanner 700 sensor..CSTCST fil

Seite 15 - ZScan Software installation

20ReferencesTo draw a surface in STL format, the system uses many small triangles. Eachtriangle is formed by 3 vertices represented in a 3D coordinate

Seite 16 - Figure 2.2

21Figure 2.11 - ZScan user interfaceMenuFigure 2.12 - Menu barFile: New Session Start a new session.Open SessionOpen an existing session file (.CSF)

Seite 17

22Edit: (options will appear only when available) Copy PositioningFeatures Copy features from current to a new scan Edit ModeChanges edition mode (I

Seite 18 - Figure 2.4

23Configure: Sensor ConfigurationSensor configuration according to the color andtexture of the object being scanned Sensor CalibrationScanner calibr

Seite 19

24Stop Scan: Stop data acquisition.Reset Scan: Reset the current scan.Positioning Features functionalitiesOpen Features: Open existing positioning tar

Seite 20 - ZScan software removal

25Rectangle: Uses a rectangle for selection.Freeform: Uses a custom form for the selection.Brush: A brush is used for selection. 3 sizes of brushes ar

Seite 21 - General Concepts

26Scan treeVisually shows functions of the « View » menu: -Figure 2.13 - Tree viewNew scan Root node that regroups every components of the current sc

Seite 22 - Surface and Volume

27Surface When selected, the surface is displayed in the 3D Viewer. The surface is arepresentation of the object being scanned from a specific view p

Seite 23 - Figure 2.12 - Menu bar

1PLEASE READ THE COMPLETE MANUAL BEFORE USE. OPERATINGYOUR ZScanner 700 LASER SCANNER USING PROCEDURES OTHERTHAN THOSE SPECIFIED HEREIN MAY RESULT IN

Seite 24

28Feature DetailsThis expanding panel will be shownwhen a specific positioning feature nodeis selected in the tree. It containsdetailed information ab

Seite 25 - Configure:

29Surface Details and Parameters (continued)Note that changing the volume size has a direct impact on the resolution level. ClickApply to confirm the

Seite 26 - Selection functionalities

30This expanding panel will be shownwhen the Recycle Bin root node isselected in the tree. It contains generalinformation about the deleted facets.Fig

Seite 27 - Facets functionalities

31 Move Volume ModeClick both buttons to rotate the volumeon the optical axis of the current view point.Edition Mode Shortcuts Shift + SelectionUnse

Seite 28 - Positioning Features

32Figure 2.23 - Sensor configuration windowTo configure the sensor correctly, the parameters should be set to have amajority of detected laser points

Seite 29

33Sensor CalibrationThis tool is used to verify and optimize sensor calibration.Figure 2.24 - Sensor calibrationTo complete the optimization process,

Seite 30 - Reference Details

34Build ReferenceThis tool is used to manually build a new reference that could be used as theorigin of the new reference frame for the facets.Figure

Seite 31 - Facets details and parameters

35Scanning proceduresObject preparationApplying targetsIt is essential to prepare the object prior to scanning. Reflective targets must beaffixed rand

Seite 32

36Reference targetsIt is now possible to use special reference targets on the part to insert referencesrecognized automatically by ZScan. These refere

Seite 33 - Sensor Configuration

37Starting the Software Connect the scanner to the system as explained in section 2.2. To start, launch the ZScan application by clicking on the ZSc

Seite 34

2This system uses a class II laser which is considered eye and skin safe but cancause eye damage if exposed directly for a prolonged time. Natural hum

Seite 35 - Sensor Calibration

38Surface DetailsDisplays a summary of the current settings: dimensions of the volumebounding box and the current resolution.Surface Parameters Adjus

Seite 36 - Build Reference

39Figure 3.5 - Sensor configuration windowTwo settings modes are possible: manual and automatic.In manual mode, trigger towards the surface to be digi

Seite 37 - Scanning procedures

40Importing positioning targetsIt is possible to import previously acquired positioning model in ZScan. From the1.2 version, it will now be possible t

Seite 38 - Reference targets

41Proper digitizing distanceThe Distance meterWhile digitizing an object, a meter displayed on the screen illustrates the distancebetween the scanner

Seite 39 - Starting the Software

42Figure 3.8 - Graphic and physical representation of the scanner too far from the surfaceWhen the scanner is too close to or too far from the surface

Seite 40 - Surface Parameters

43Editing the scanTo delete a part of the scanned object, set ZScan to Facets mode. In the Menu,View - Facets or click on Facets in the tree. Set the

Seite 41 - Configuring the sensor

44TroubleshootingYou can use the Troubleshooter to help you find a solution. Also, please check theZScanner 700 User website for additional support.I

Seite 42 - Acquiring data

45I receive an error message while scanning telling me that an internal errorhas occurred.There is a high probability that this error message was trig

Seite 43 - The Distance meter

46work for any reason, set the resolution to low, save your session, restart ZScanand try to open it.I am experiencing slow frame rates when scanning.

Seite 44

3WARNING LABELS AND LOCATIONSFigure I - Laser labels and locations

Seite 45 - Saving your work

4WHAT’S NEWZScan 1.3 Full compatibility with Windows Vista 32 bits OS Enhanced, more functional and efficient facet edition mode New reliable, fast

Seite 46 - Troubleshooting

5System OverviewSystem descriptionThe ZScanner 700 system includes the following components: ZScanner 700 scanner Ergonomic stand Reflective target

Seite 47

6Figure 1.1 - ZScanner 700

Seite 48

7General careThe ZScanner 700 contains optical precision parts and must be handled withcare to avoid damage to the components or the calibration syste

Kommentare zu diesen Handbüchern